Typ Ord.-No. Measurement Ranges Bandwidth DC-Measurement
Accuracy
Current Rise and
Fall Time
Max. Working
Voltage
TT-CC 220 15322 100 mV/A - 10 mV/A DC - 300 kHz ±3% ±50mA @ 100 mV/A
±4% ±50mA @ 10 mV/A
±15% max @ 10 mV/A
10 A - 100 A 1.2 µs 600 VAC RMS CAT II
300 VAC RMS CAT III
TT-CC 550 15355 200 mV/A - 20 mV/A DC - 500 kHz ±3% ±30mA @ 200 mV/A
±4% ±300mA @ 20 mV/A
±15% @ 200 mV/A
5 A - 50 A 0.7 µs 600 VAC RMS CAT II
300 VAC RMS CAT III
TT-CC 770 15377 500 mV/A - 50 mV/A DC - 1 MHz ±3% ±20mA @ 500 mV/A
±4% ±200mA @ 50 mV/A
±15% @ 50 mV/A
7 A - 70 A 0.35 µs 600 VAC RMS CAT II
300 VAC RMS CAT III
TT-CC 990 15399 1 V/A - 100 mV/A DC - 1.5 MHz ±3% ±10mA @ 1 V/A
±4% ±100mA @ 100 mV/A
4 A - 40 A 0.23 µs 600 VAC RMS CAT II
300 VAC RMS CAT III

Download Comparisan Chart

Current Probes for Oscilloscopes

TT-CC 220

accessories supplied

Measurement Ranges100 mV/A - 10 mV/A
Current10 A - 100 A
DC Measurement Accuracy±3% ±50 mA @ 100 mV/A
±4% ±50 mA @ 10 mV/A
±15% max @ 10 mV/A
BandwidthDC - 300 kHz
Rise and Fall Time1.2 µs
Max. Working Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Max. Floating Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Battery-Typ9 V Alkaline (NEDA 1604, IEC 6LR61)
Battery Life8 h
Operating Temperature0 bis 50 °C
Storage Temperature-20 bis 80 °C
Max. Operating Humidity0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
Pollution Degree2
Maximum Conductor11 mm
Dimensions (L x B x H)265 mm x 80 mm x 36 mm
Weight260 g
AccessoriesHardcase and Power Supply included
Manual
Order number15322

TT-CC 550

accessories supplied

Measurement Ranges200 mV/A - 20 mV/A
Current5 A - 50 A
DC Measurement Accuracy±3% ±30 mA @ 200 mV/A
±4% ±300 mA @ 20 mV/A
±15% @ 200 mV/A
BandwidthDC - 500 kHz
Rise and Fall Time0.7 µs
Max. Working Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Max. Floating Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Battery-Typ9 V Alkaline (NEDA 1604, IEC 6LR61)
Battery Life8 h
Operating Temperature0 bis 50 °C
Storage Temperature-20 bis 80 °C
Max. Operating Humidity0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
Pollution Degree2
Maximum Conductor11 mm
Dimensions (L x B x H)265 mm x 80 mm x 36 mm
Weight260 g
AccessoriesHardcase and Power Supply included
Manual
Order number15355

TT-CC 770

accessories supplied

Measurement Ranges500 mV/A - 50 mV/A
Current7 A - 70 A
DC Measurement Accuracy±3% ±20 mA @ 500 mV/A
±4% ±200 mA @ 50 mV/A
±15% @ 50 mV/A
BandwidthDC - 1 MHz
Rise and Fall Time0.35 µs
Max. Working Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Max. Floating Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Battery-Typ9 V Alkaline (NEDA 1604, IEC 6LR61)
Battery Life6 h
Operating Temperature0 bis 50 °C
Storage Temperature-20 bis 80 °C
Max. Operating Humidity0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
Pollution Degree2
Maximum Conductor10.3 mm
Dimensions (L x B x H)262 mm x 80 mm x 36 mm
Weight310 g
AccessoriesHardcase and Power Supply included
Manual
Order number15377

TT-CC 990

accessories supplied

Measurement Ranges1 V/A - 100 mV/A
Current4 A - 40 A
DC Measurement Accuracy±3% ±10 mA @ 1 V/A
±4% ±100 mA @ 100 mV/A
BandwidthDC - 1.5 MHz
Rise and Fall Time0.23 µs
Max. Working Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Max. Floating Voltage600 VAC RMS CAT II /
300 VAC RMS CAT III
Battery-Typ9 V Alkaline (NEDA 1604, IEC 6LR61)
Battery Life4 h
Operating Temperature0 bis 50 °C
Storage Temperature-20 bis 80 °C
Max. Operating Humidity0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
Pollution Degree2
Maximum Conductor10.3 mm
Dimensions (L x B x H)262 mm x 80 mm x 36 mm
Weight310 g
AccessoriesHardcase and Power Supply included
Manual
Order number15399

Accessories Current Probes

TT-CC-NT - Power Supply

Order number15340
Cable Length190 cm

TT-CC-B100 - finger-safe Test Lead BNC/BNC

Order number15341
Cable Length100 cm

TT-CC-MA - finger-safe Test Adapter BNC/4 mm plug

Order number15343

TT-CC-HC - Hardcase

Order number15342
Dimensions (B x T x H)340 mm x 280 mm x 80 mm

All specifications and characteristics are subject to change without notice.